DFL-1/DFL-5 online float-type density meters

For ultra-high-resolution/high-resolution fluid measurement

DFL-1 ultra-high-resolution fluid measurement densitometer

DFL-1

  • The online densitometer for high-sensitivity measurement of fluid density.
    Ultra-high-resolution density measurement with a maximum sensitivity of 0.00005 g/cm³.
    The density measurement determines the quality and purity of measured fluids and the degree to which reactions have progressed.
  • Measurement is performed by the converting float buoyancy into air pressure, requiring no electricity.
  • The function of automatic compensating performs for the changing density caused by increases or decreases in measured fluids temperature.
  • Available to measuring pressurized fluids.
    Wet measurement method available to measuring at pressures of up to 1.961 MPa (20 kgf/cm²).
  • Simple balance scale design and structure for easy maintenance.
  • Track records have been over 2,100 units since 1970.

DFL-1 specifications

Measurement range Span can be set as desired between 0.01 and 0.1 g/cm³
Operating temperature Max.100℃
Operating pressure Max.1.961MPa (20 kgf/cm²)
Correction range Within ±20°C of measurement fluid reference temperature
Output signal 20 to 100 kPa (can output 4 to 20 mADC when using pneumatic-electro converter)
Measurement fluid flow rate 5 L/min or less
Measured fluid viscosity 2 to 3 mPa・s (cp) or less
Installation method Installation method
Measurement precision Within ±0.5% of span
Unit weight Approx. 45 kg (without float chamber)/approx. 65 kg (with float chamber)
Dimensions Individual design (without float chamber)/400 mm (W) x 220 mm (D) x 1,300 mm (H) (with float chamber)

DFL-5 high-resolution fluid measurement densitometer

DFL-5

  • The online densitometer for high-sensitivity measurement of fluid density.
    High-resolution density measurement with a maximum sensitivity of 0.00025 g/cm³.
    The density measurement determines the quality and purity of measured fluids and the degree to which reactions have progressed.
  • Measurement is performed by the converting float buoyancy into air pressure, requiring no electricity.
  • The function of automatic compensating performs for the changing density caused by increases or decreases in measured fluids temperature.
  • More compact and lower price than the DFL-1.
  • Simple design and structure for easy maintenance.
  • Track records have been over 2,100 units since 1970.

DFL-5 specifications

Measurement range Fixed span selectable from following options: 0.05, 0.1, 0.25, 0.5 g/cm³
Operating temperature Max.100℃
Operating pressure Atmospheric pressure
Correction range Within ±20°C of measurement fluid reference temperature
Output signal 20 to 100 kPa (can output 4 to 20 mADC when using pneumatic-electro converter)
Measurement fluid Flow rate 5 L/min or less
Measured fluid viscosity 2 to 3 mPa・s (cp) or less
Installation method Installation method
Measurement precision Within ±0.5% of span
Unit weight Approx. 10 kg (without float chamber)/approx. 30 kg (with float chamber)
Dimensions Individual design (without float chamber)/245 mm (W) x 140 mm (D) x 1,330 mm (H) (with float chamber)