Water Quality AnalyzersTotal Organic Carbon (TOC) Automatic Analyzers
TOC-200 series
TOC-200 series of water quality analyzers
Available for all types of samples, from source samples to discharge monitoring samples
The Toray TOC automatic analyzers rapidly and accurately perform automatic analysis of total organic carbon content such as in rivers, lakes and marshes, sea areas and plant wastewater, in either online or offline.
The TOC analyzers use Toray’s unique low temperature sealed combustion system, providing stable measurement for long periods. These devices, are based on our technology over four decades and plentiful track records, are economical priced, easy operating, space saving by size reduction.
Application
Our TOC analyzers support various measurements points, from high concentration to low concentration, such as from wastewater to rainwater, and providing stable measurement.
Features
- 650°C sealed combustion, the industry’s lowest temperature, reduces the frequency with which catalyst maintenance is required
- Unique catalyst design and pre-processing filter ensure stable measurement of samples containing high concentrations, such as suspended matter and seawater samples
- New sample line cleaning function, which uses acidic solution and minimum sample tube internal diameter of ⌀2 mm, helps prevent contaminants from impacting results and reduces adherence of suspended matter
- Lineup of four models to suit individual uses
Specifications
Shared specifications | TOC-200 series | |
---|---|---|
Measurement range | 0-5 to 1,000 mg/L (optional range: 0-150 to 3,000 mg/L) | |
Measurement mode | Online TOC, Offline TOC, and Offline TC | |
Measurement cycle | 4 minutes or greater (TC measurement), 5 minutes or greater (TOC measurement) | |
Measurement method | Total carbon measurement | Automatic intermittent sealed combustion infrared analysis |
Inorganic carbon removal | Automatic intermittent hydrochloric acid aeration method | |
Measurement value conversion function | Contains function for converting from TOC to COD or BOD (conversion value = a+bx Coefficients a and b are customer-defined) |
|
Linearity/repeatability | The greater of the following: ±2% FS or less or ±0.15 mg/L or less | |
Zero/span stability | The greater of the following: ±2% FS/day or ±0.15 mg/L/day or less | |
Ambient temperature change | The greater of the following: ±2% FS/5°C or less or ±0.15 mg/L/5°C or less | |
Measurement value output | DC 4 to 20 mA (load resistance: 0 to 500 Ω) | |
Transmission output | USB (options: RS-232C, RS-485) | |
Input signal | Non-voltage contact, DC24V Items: External link, stop measurement, release alarm |
|
Output signal | Non-voltage contact, AC 125 V 1 A (resistance load) Items: Maintenance in progress signal, Power failure signal, External pump signal, Count signal, and Selectable output |
|
Abnormal measurement value (selectable output) | Upper upper limit, upper limit, lower limit, lower lower limit | |
Device error (selectable output) | Abnormal temperature, sample supply interrupted, pipe cleaning fluid supply interrupted (can be assigned as desired for major/minor failures) (Options: Gas pressure drop, Test reagent supply interrupted, and Cleaning fluid supply interrupted) |
|
Other options | Recording meter, automatic calibration function, separate printer, electrical component air purge, load amount calculation unit | |
Sample conditions | ACF inlet: 0.05 to 0.15 MPa, 3 L/min or greater, 1 to 50°C ACF inlet: 0.05 to 0.15 MPa, 3 L/min or greater, 1 to 50°C (Please consult with us regarding situations in which the temperature will normally be 40°C or greater) (Device inlet: 0.02 to 0.1 MPa, 500 mL/min or greater, 1 to 50°C) |
|
Offline sample amount | 200 to 500 mL/3 measurements (for offline TOC measurement roughly 1,000 mL/3 measurements) | |
Test reagent | For 2 mol/L-HCL5 minute measurement interval, approximately 5 L/month For 60 minute measurement interval approximately 5 L/year (if pipe cleaning is not performed) |
|
Cleaning fluid | Distilled water | |
Reverse cleaning water | 0.1 to 0.4 MPa flow: 3 to 5 L/min, 1 to 50°C (do not use reverse cleaning water which contains organic carbon or detritus, etc., or which chemically reacts with samples) |
|
Pipe cleaning water | 0.02 to 0.05 MPa, 0.4 to 0.6L/min, 1 to 50°C (do not use water which contains organic carbon or detritus, etc.) |
|
Carrier gas | 0.3 MPa nitrogen (99.9% or greater) or instrumentation compressed air Approx. 7 Nm3 /month (when using instrumentation compressed air a CO2elimination filter is required, and the instrumentation compressed air cannot contain moisture or oil) |
|
Power | AC 100 V±10 V, 600 VA, power consumption: Approx. 350 W (multistream model: 450 W) | |
Installation location | Indoors 1 to 40°C (avoid environments with corrosive gasses such as hydrogen sulfide) | |
External dimensions/weight | 550 mm (W) ×538 mm (D)×1430 mm (H)mm(not including 70 mm casters), Approx. 100 kg | |
Anchor mounting dimensions | 4-φ13 510 mm (W) ×457 mm (D) | |
Service area | Front, left, and right sides 600 mm (not needed for rear side) |
Individual model specifications | TOC-200S | TOC-200SD | TOC-200M | TOC-200MD |
---|---|---|---|---|
Stream switching | 1 stream | 1 stream | Up to 8 streams | Up to 8 streams |
Dilution function | None | 2 to 20x | None | 2 to 20x |
Number of selectable outputs | 8 | 8 | 16 | 16 |
Measurement mode | - | - | Cycle measurement, random measurement | |
Multistream input signal | - | - | Per-stream measurement start signal input | |
Multistream output signal | - | - | Per-stream abnormal measurement value signal output |
Automatic cleaning filter
Our automatic cleaning filters, developed in-house, are sample filtration preprocessing devices which consist of net-less elements made up of stacked circular disks and cleaning blades. The ACF element component uses a roughly 100 gauge net (equivalent to 147 μm) to catch matter suspended in samples.
The suspended matter is scraped off by the cleaning blades, washed off by the flow of excess sample, and evacuated via the drain.
Options such as a reverse cleaning function using cleaning water and functions for controlling element pass-through time are also available to reduce the amount of element clogging.