Oxygen AnalyzersOxygen Analyzers for Baking Furnaces, N2 Reflow Ovens, and Dirty Gas
RF-400, LC-750H/PC-111
Model: RF-400
- New particle filter
Replaceable without removing the oxygen analyzer from the device - Special filter
- Improves oxygen sensor durability
- Wide AC range
Supports 100 V to 240 V AC power - Convenient measurement range
Measurement range of 0 to 10,000 ppm, commonly used in nitrogen reflow systems (0–1% range is also selectable) - Compact and easy to install
Shorter depth than conventional devices. Save space.
RF-400 specifications
Measurement principle | Zirconia concentration cell type | ||
---|---|---|---|
Type | Desktop type/panel mounted type | ||
Display system | 4-digit digital display (concentration display) | ||
Measurement range | 0-1 / 10 / 100 / 1000 / 10000ppm(1) / 10 / 100vol%O2 10-20~10-0atm Automatic range |
||
Repeatability | Within ±1% of full scale; 1%≦ sample gas ≦100% Within ±2% of full scale; 10 ppm≦ sample gas ≦1% Concentrations under 10 ppm are out of warranty. |
||
Sampling method | Continuous suction with built-in pump | ||
Sample gas requirements | Pressure | Pressurization of 30 KPa or less | |
Flow rate | 1,000~2,000mL/min | ||
Humidity | Dew point below ambient temperature | ||
Temperature | 0 to 50°C | ||
Others | Must not contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable substances (including gas), oil or moisture | ||
Reference gas | Atmosphere | ||
Recorder output | Oxygen concentration output | 4-20mA; insulated,load resistance of 550 Ω or less Recorder output range taken as full scale, and oxygen concentration given in linear output |
|
Output range | 0-100%, 0-10%, 10000ppm, 0-100ppm, 0 Automatic/fixed range | ||
Transmission output | RS-232C (optional) | ||
Alarm output | FAIL (device error) | 1 point | Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less Contact point closes when device error occurs (contact point operation is adjustable) |
ALM (concentration alarm) | 2 points (H/L) | Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less Contact point closes when alarm occurs (contact point operation is adjustable) |
|
RDY (warmup signal) | 1 point | Non-voltage contact; contact capacity: 30 V DC/AC or less, 0.5 A or less
|
|
Warmup time | 5 minutes or less | ||
Dimensions | Body | 210 mm (W) ×134 mm (H)×300 mm (D)(excluding projecting parts and filter) | |
Weight | Approx. 6.5 kg | ||
Gas connection | INLET | Rc1/4 | |
BYPASS OUT | Rc1/4 | ||
OUTLET | Rc1/4 | ||
Power | 100 to 240 V AC±5%, 200 V A 50 Hz/60 Hz±2% |
- The model with a built-in gas suction pump in LC-750H PC-111 set model is best for high and medium concentration dirty gas measurement.
LC-750H/PC-111 specifications
Measurement principle | Zirconia concentration cell type | ||
---|---|---|---|
Type | Desktop type/panel mounted type | ||
Display system | Digital 4-digit display or analog display | ||
Measurement range | Digital display | 0-0.1 / 1 / 10 / 100% fixed range |
|
Analog display | 0-0.5/5/10/25% | ||
Tolerance | Within ±2% of full scale; range of 0-2% or more Within ±3% of full scale; range of less than 0-2% |
||
Sampling method | Continuous suction with built-in pump | ||
Sample gas requirements | Pressure | Pressurization of 14 KPa or less | |
Flow rate | 1,000~2,000mL/min | ||
Humidity | Dew point below ambient temperature | ||
Temperature | -10 to 100°C | ||
Others | Must not contain corrosive gas (fluorine gas, chlorine gas, sulfuric gas, etc.), gas containing organic silicone, flammable substances (including gas), oil or moisture | ||
Reference gas | Atmosphere | ||
Recorder output | Oxygen concentration output | 4-20 mA or 0-10 V 4-20 mA: load resistance of 600 Ω or less 0-10 V: load resistance of 100 Ω or more |
|
Transmission output | None | ||
Alarm output | ALM (concentration alarm) | 2 points (H/L) | Non-voltage contact; contact capacity: AC 110, DC 24 V 3 A (resistance load) |
Warmup time | 20 minutes or less | ||
Dimensions | Body:210 mm (W) ×300 mm (H)×327 mm (D) (excluding projecting parts) | ||
Weight | Approx. 10 kg | ||
Gas connection | INLET | Rc1/4 | |
BYPASS OUT | Rc1/4 | ||
OUTLET | Rc1/4 | ||
Power | AC 100 V±10%, 200 VA 50 Hz/60 Hz |